Discipline hub

Electrical Center

Everything on the site for electrical and ELV engineers in one place: calculators in the order you design, site guides, checklists, practice exams, careers and the standards to keep at hand.

25 calculators15 guides10 checklists2 practice exams

Free · PDF

Site Engineer's Quick Reference

Two A4 pages to print or keep on your phone: power formulas, fault level, MCB curves, cables, motors, ELV, submittal codes, FIDIC notices, permits, heat rules, concrete basics.

2 A4 pages · English and Arabic · edition Nov 2026 · preliminary, check your contract and specification

Calculators in design order

Follow the steps from left to right. Each calculator opens with typical values; results are preliminary, verify before design.

Where each calculator fits

A typical LV distribution. Tap a number to open the calculator for that point.

Typical LV distribution, single-line diagramMV supply and transformer, standby generator, ATS, main LV switchboard with power factor correction, a sub-board with lighting and socket circuits, a motor feeder and a UPS for critical loads. Numbered markers open the calculators. MV supply Transformer GGenerator ATS Main LV switchboard (MDB) PF correction Sub-board (SMDB) SocketsLighting MMotor UPSCritical loads 1. Transformer Sizing12. Transformer Fault Level23. Generator Sizing34. Earth Rod Resistance45. PF Correction56. Breaker Selection67. Cable Sizing78. Voltage Drop89. Fault Current at Cable End910. Earth Fault Loop Impedance (Zs)1011. Earth Conductor Size1112. Motor Current1213. UPS & Battery1314. Lighting Lumen Method14 Simplified, not to scale
  1. Transformer Sizing
  2. Transformer Fault Level
  3. Generator Sizing
  4. Earth Rod Resistance
  5. PF Correction
  6. Breaker Selection
  7. Cable Sizing
  8. Voltage Drop
  9. Fault Current at Cable End
  10. Earth Fault Loop Impedance (Zs)
  11. Earth Conductor Size
  12. Motor Current
  13. UPS & Battery
  14. Lighting Lumen Method

All electrical, ELV and solar calculators 25

Voltage DropCheck a cable run against the allowable drop✓ Engineer reviewedCable SizingSmallest copper XLPE cable for a design current✓ Engineer reviewedNeutral Sizing with Harmonics4-core cable size when third harmonics load the neutralEarth Fault Loop Impedance (Zs)Maximum Zs for an MCB and a check of the measured value✓ Engineer reviewedInsulation Resistance CheckTest voltage, minimum IR and polarisation index✓ Engineer reviewedkW · kVA · AmpsConvert between power and current✓ Engineer reviewedTransformer Fault LevelFull-load and short-circuit current✓ Engineer reviewedPF CorrectionCapacitor bank size to reach target PF✓ Engineer reviewedMotor CurrentFull-load and starting current✓ Engineer reviewedGenerator SizingStandby generator kVA from connected load✓ Engineer reviewedUPS & BatteryUPS rating and battery Ah for autonomy✓ Engineer reviewedLighting Lumen MethodNumber of luminaires for a target lux✓ Engineer reviewedEarth Rod ResistanceSingle rod resistance and rods needed✓ Engineer reviewedCable Tray FillPercentage fill of a cable tray✓ Engineer reviewedConduit FillCables per conduit size✓ Engineer reviewedFault Current at Cable EndShort-circuit current at a remote board✓ Engineer reviewedSolar PV & BatteryArray size and battery bank for a daily load✓ Engineer reviewedTransformer SizingkVA rating from connected load✓ Engineer reviewedBreaker SelectionRating that protects the cable✓ Engineer reviewedEarth Conductor SizeAdiabatic check for protective conductors✓ Engineer reviewedFiber Loss BudgetExpected and maximum link loss✓ Engineer reviewedCCTV StorageRecording storage and network bandwidth✓ Engineer reviewedPoE Switch BudgetPower for cameras, phones and access points✓ Engineer reviewedFire Alarm BatteryStandby battery for a fire alarm panel✓ Engineer reviewedPA Amplifier Sizing100 V line amplifier power per zone✓ Engineer reviewed

Guides 15

Site checklists 10

Practice exams 2

Careers 9

Standards and library 6