Trench Bedding & Backfill per Metre

Excavation, granular bedding and surround, and backfill for a pipe trench

Design data
mm
m
m
mm
mm
m
ResultPreliminary · verify before design
Granular bedding and surround per metre0.649 m³/m64.9 m³ compacted for 100 m
Within limitTrench width leaves room to compact beside the pipe
Excavation per metre1.425 m³/m
Backfill above the surround per metre0.698 m³/m
Excavation for the length142.5 m³
Granular, compacted, for the length64.9 m³
Granular to order (loose)81.1 m³
Backfill for the length69.8 m³
Surplus to remove (pipe + granular volume)72.7 m³ (bank)

Vertical-sided trench. Sloped or shored trenches, over-excavation of soft spots and sand / cement-bound surround need their own quantities. Bedding class, material grading, layer thickness and compaction follow the pipe standard and the project specification.

What to verify before design ↓

Verify before using in design

  • Trench width, bedding class and compaction against the specification and pipe standard.
  • Shoring or battering for trenches deeper than 1.2 m (permit and temporary works design).
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Nov 2026✓ Tested against worked examples✓ Reviewed by a senior engineer · Nov 2026

Formula

Excavation = B·H Granular = B·(b + D + s) − π·D² ÷ 4 Backfill = B·(H − b − D − s)

Standards and references

  • EN 1610 (construction and testing of drains and sewers)
  • Pipe maker's installation guide (bedding class)
  • Project specification (granular grading, compaction)

Assumptions

  • Vertical-sided trench of constant width; granular bedding and surround to the stated thickness; volumes compacted unless stated.

Inputs and units

Pipe outside diametermm50–2000
Trench width at the pipem0.3–3
Trench depth (ground to trench bottom)m0.5–6
Bedding under the pipemm100–300
Granular surround above the crownmm100–400
Trench lengthm1–2000
Loose-to-compacted factor for imported granular1–1.4

Typical range: last column

Worked example (default values)

  • Pipe outside diameter315 mm
  • Trench width at the pipe0.95 m
  • Trench depth (ground to trench bottom)1.5 m
  • Bedding under the pipe150 mm
  • Granular surround above the crown300 mm
  • Trench length100 m
  • Loose-to-compacted factor for imported granular1.25
Granular bedding and surround per metre0.649 m³/mTrench width leaves room to compact beside the pipe

Next steps

More Utilities & infrastructure calculators

Found an error? Tell us

Describe the problem briefly (the wrong value, the right one, and the reference if you have it). The page name is sent automatically.