Street Lighting Spacing

Column spacing for a target average illuminance on the road

Design data
lm
m
lux
m
m
Settings & basis
ResultPreliminary · verify before design
Maximum spacing between columns35 mAverage 15.0 lux at this spacing
ReviewSpacing 3.5 × the mounting height: check uniformity in the lighting software
Exact spacing for the target35.1 m
Spacing ÷ mounting height3.50
Column positions over the length30
Luminaires over the length30
Total lamp output per km360 klm

A first sizing by the lumen method for illuminance classes (lux). Single-sided and staggered layouts both count one luminaire per spacing across the road, so they give the same spacing; opposite layout counts two. Traffic routes designed by road luminance (EN 13201 M classes), uniformity, glare (TI) and surround ratio need a lighting design program with the luminaire's photometric file. The lighting class comes from the road authority.

What to verify before design ↓

Verify before using in design

  • Lighting class, uniformity, glare (TI) and surround ratio in a lighting design program with the photometric file.
  • Column positions against junctions, bends, accesses and buried services.
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.1 · Nov 2026Basis last checked: Nov 2026✓ Tested against worked examples✓ Reviewed by a senior engineer · Nov 2026

Formula

S = n·Φ·UF·MF ÷ (E·W) n = 1 single-sided or staggered, 2 opposite pairs

Standards and references

  • EN 13201-2 (road lighting: performance requirements)
  • CIE 115 (lighting of roads for motor and pedestrian traffic)
  • Road authority lighting standard

Assumptions

  • Lumen method: average illuminance over the road width; one luminaire type at one spacing.

Inputs and units

Luminaire outputlm1000–40000
Road width litm3–30
Required average illuminancelux5–50
Utilisation factor0.2–0.7
Maintenance factor0.6–0.95
Mounting heightm4–15
Road lengthm50–10000
Arrangement—

Typical range: last column

Worked example (default values)

  • Luminaire output12000 lm
  • Road width lit7.3 m
  • Required average illuminance15 lux
  • Utilisation factor0.4
  • Maintenance factor0.8
  • Mounting height10 m
  • Road length1000 m
  • ArrangementSingle-sided
Maximum spacing between columns35 mSpacing 3.5 × the mounting height: check uniformity in the lighting software

Next steps

More Utilities & infrastructure calculators

Found an error? Tell us

Describe the problem briefly (the wrong value, the right one, and the reference if you have it). The page name is sent automatically.