Outrigger Pad Bearing

Ground pressure under a crane outrigger and pad size needed

Design data
t
m
m
kPa
ResultPreliminary · verify before design
Bearing pressure under the pad196 kPa441 kN on 2.25 m²
ReviewWithin 200 kPa allowable
Outrigger load441 kN
Pad area needed2.21 m²
Square pad side needed1.49 m
Utilisation of ground capacity98 %

Take the outrigger load from the crane maker's outrigger-load calculator for the actual lift, not the hook load. The pad must be stiff enough to spread the load over its full area; check buried services, voids, slopes and edges of excavations. Allowable pressure comes from a geotechnical assessment.

What to verify before design ↓

Verify before using in design

  • Get the allowable bearing pressure from a geotechnical assessment and check for services, voids and slopes.
  • Use the crane maker's outrigger-load calculator for the actual lift and slew range.
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Oct 2026✓ Tested against worked examples

Formula

p = F ÷ (L × B) A needed = F ÷ q allowable

Standards and references

  • BS 7121-1 and CPA guidance on ground conditions for cranes
  • Crane maker's outrigger-load data

Assumptions

  • Uniform pressure under a stiff pad; vertical outrigger load only.

Inputs and units

Maximum outrigger loadt
Pad (mat) lengthm
Pad (mat) widthm
Allowable ground bearing pressurekPa50–1000

Typical range: last column

Worked example (default values)

  • Maximum outrigger load45 t
  • Pad (mat) length1.5 m
  • Pad (mat) width1.5 m
  • Allowable ground bearing pressure200 kPa
Bearing pressure under the pad196 kPaWithin 200 kPa allowable

Next steps

More Plant & temporary works calculators

Found an error? Tell us