Sewer Flow & Pipe Check

Peak sewage flow, depth of flow and velocity in a gravity sewer

Design data
persons
L/person/day
%
% of average
mm
%
Settings & basis
ResultPreliminary · verify before design
Peak design flow38.7 L/sAverage 11.57 L/s × peak factor 3.25 + 10 % infiltration
Within limitDepth 0.58 D and velocity 0.92 m/s at peak flow
Depth of flow at peak (y/D)0.58
Velocity at peak flow0.92 m/s
Full-bore capacity61.2 L/s
Full-bore velocity0.87 m/s
Peak flow ÷ full capacity63 %
Peak factor (Harmon)3.25

Uses Harmon's peak factor and Manning's equation. Minimum and maximum velocities, depth limits and per-capita flows are set by the sewerage authority; check yours.

What to verify before design ↓

Verify before using in design

  • Check the authority's minimum velocity (self-cleansing), maximum depth ratio and minimum pipe size.
  • Check H2S risk on long, flat runs and at rising main discharges.
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Oct 2026✓ Tested against worked examples

Formula

PF = 1 + 14 ÷ (4 + √P) (P in thousands) Q = (1/n) · A · R^(2/3) · S^(1/2) (partly full circular pipe)

Standards and references

  • Harmon peak factor (as used in many design manuals)
  • Manning's equation for part-full circular pipes
  • EN 752 (drain and sewer systems outside buildings)

Assumptions

  • Peak factor by Harmon's formula; infiltration as a percentage of average flow.
  • Uniform flow in a circular pipe with constant Manning's n.

Inputs and units

Population servedpersons
Water consumptionL/person/day
Return to sewer%60–100
Infiltration allowance% of average0–50
Pipe internal diametermm
Gradient%0.1–10
Manning's n0.009–0.016
Maximum depth of flow—

Typical range: last column

Worked example (default values)

  • Population served5000 persons
  • Water consumption250 L/person/day
  • Return to sewer80 %
  • Infiltration allowance10 % of average
  • Pipe internal diameter300 mm
  • Gradient0.4 %
  • Manning's n0.013
  • Maximum depth of flow0.75 D
Peak design flow38.7 L/sDepth 0.58 D and velocity 0.92 m/s at peak flow