Piping Pressure Test

Hydrostatic or pneumatic test pressure, fill volume and stored energy

Design data
barg
mm
m
m
Settings & basis
ResultPreliminary · verify before design
Test pressure at the high point60.0 barg1.5 × 40.0 barg × 1.00
Within limitHold at least 10 minutes, then examine every joint
Pressure at the low point61.0 barg
Water volume to fill4.66 m³
Minimum hold time (B31.3)10 min

ASME B31.3 §345. Make sure the test pressure does not stress any component beyond yield, and that flanges, valves and instruments in the loop are rated for it or isolated. A pneumatic test starts with a low preliminary check and rises in steps. The project's test procedure and test-pack rules govern hold times and acceptance.

What to verify before design ↓

Verify before using in design

  • Check that no component (flanges, valves, instruments, vessels) is overstressed or over its rating at the low-point pressure.
  • Pneumatic tests need the owner's approval and a safety distance calculation.
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Oct 2026✓ Tested against worked examples

Formula

Hydrostatic PT = 1.5 × P × (ST ÷ S), ST ÷ S ≤ 6.5 Pneumatic PT = 1.1 × P Low point = PT + ρ g Δz

Standards and references

  • ASME B31.3 §345 (leak testing)
  • ASME PCC-2 Article 5.1 (pressure testing, stored energy)
  • Project test procedure and test-pack requirements

Assumptions

  • Test pressure is set at the high point; the low point sees the extra water head.
  • Stored energy uses adiabatic expansion of air (k = 1.4).

Inputs and units

Design pressurebarg
Test medium—
Stress ratio ST ÷ S (test temperature ÷ design temperature)1–6.5
Pipe inside diametermm10–2000
Length of the test sectionm1–20000
Height difference, high point to low pointm

Typical range: last column

Worked example (default values)

  • Design pressure40 barg
  • Test mediumHydrostatic (water)
  • Stress ratio ST ÷ S (test temperature ÷ design temperature)1
  • Pipe inside diameter154.1 mm
  • Length of the test section250 m
  • Height difference, high point to low point10 m
Test pressure at the high point60.0 bargHold at least 10 minutes, then examine every joint