Pipe Wall Thickness (B31.3)

Minimum wall for internal pressure, with allowance and mill tolerance

Design data
barg
mm
MPa
mm
mm
Settings & basis
ResultPreliminary · verify before design
Minimum nominal wall thickness6.18 mm2.41 mm for pressure + 3.0 mm allowance, then mill tolerance
Within limitSelected 7.11 mm is enough
Pressure design thickness t2.41 mm
Required thickness tm = t + c5.41 mm
Selected wall after tolerance and allowance3.22 mm
Max. allowable pressure, selected wall53.6 barg

ASME B31.3 straight pipe under internal pressure, with W = 1 (no weld strength reduction) and Y = 0.4 (valid for t < D/6 and metal below 482 °C). Take S and E from Tables A-1 and A-1B for the exact material and temperature. External pressure, bends, branches and other loads need separate checks.

What to verify before design ↓

Verify before using in design

  • Confirm the wall and schedule in the project piping class.
  • Bends, branches, external pressure and sustained or thermal loads need their own checks (stress analysis).
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Oct 2026✓ Tested against worked examples

Formula

t = P × D ÷ (2 (S × E × W + P × Y)) tm = t + c nominal ≥ tm ÷ (1 − mill tolerance)

Standards and references

  • ASME B31.3 Process Piping, §304.1.2
  • ASME B36.10M / B36.19M (pipe dimensions and schedules)
  • Project piping class (material specification)

Assumptions

  • Straight pipe, internal pressure only; W = 1 and Y = 0.4 (t < D/6, metal below 482 °C).
  • S and E from B31.3 Tables A-1 and A-1B for the actual material and design temperature.

Inputs and units

Design pressurebarg0.5–400
Outside diametermm10–2000
Allowable stress at design temperatureMPa20–400
Weld joint quality factor E—
Corrosion and thread / groove allowancemm
Mill tolerance—
Selected nominal wall thicknessmm

Typical range: last column

Worked example (default values)

  • Design pressure40 barg
  • Outside diameter168.3 mm
  • Allowable stress at design temperature138 MPa
  • Weld joint quality factor E1.00 seamless
  • Corrosion and thread / groove allowance3 mm
  • Mill tolerance12.5 % (typical seamless pipe)
  • Selected nominal wall thickness7.11 mm
Minimum nominal wall thickness6.18 mmSelected 7.11 mm is enough