Curtain Walls & Cladding Systems
The façade keeps out sun, heat, wind, rain and sand, and it is one of the most expensive and most visible packages on a building. Most of its problems are decided at the design and submittal stage, long before the first panel arrives.
System types
- Stick system: mullions and transoms assembled on site, then glazed. Flexible, but quality depends on site work.
- Unitised system: factory-made panels, usually a floor high, hung from brackets on the slab edge. Faster and better controlled; needs crane or hoist access and careful interface design.
- Rainscreen cladding (metal, stone, ceramic, fibre-cement panels) on a ventilated cavity over an insulated backing wall.
- Point-fixed (spider) glazing, shopfronts and louvres complete most façades.
Performance specification
- Structural: wind loads from the wind study, deflection limits, dead load, building movements (inter-storey drift, slab deflection).
- Air and water tightness at stated test pressures; thermal performance (U-value, SHGC) and condensation risk.
- Acoustics, blast or security where required, and fire performance of every material and cavity barrier.
- Maintenance and access: building maintenance unit (BMU), cleaning, glass replacement.
Interfaces and submittals
- Brackets and embeds are set by the structure: get their positions and tolerances fixed early.
- Shop drawings, structural calculations, thermal and condensation reports, samples and a mock-up go through approval before fabrication.
- Interfaces with roofing, waterproofing, MEP (louvres, lighting) and fire stopping at slab edges are where leaks and fire gaps happen.