Sleeve & Opening Size

Builder's work opening for a duct, or sleeve / core for a pipe

Design data
mm
mm
mm
mm
Settings & basis
ResultPreliminary · verify before design
Minimum sleeve / core diameter214 mmNext common core-drill size: 227 mm
Pipe outside diameter114 mm
Over insulation164 mm
Next common core-drill size227 mm

Core and sleeve sizes vary by supplier; check the fire-stopping system's tested gap range for fire-rated walls and floors. Get approval before drilling structure, and scan for reinforcement and embedded services first.

What to verify before design ↓

Verify before using in design

  • Use the fire-stopping system's tested annular gap for fire-rated elements.
  • Get structural approval for openings and core-drilling in slabs, beams and walls.
  • Check the edition of each standard that your project specification calls for.
  • Confirm with manufacturer data and the approved design before construction.
Basis & methodVersion 1.0 · Nov 2026Basis last checked: Oct 2026✓ Tested against worked examples

Formula

Sleeve ID ≥ pipe OD + 2 × (insulation + clearance)

Standards and references

  • Fire-stopping system maker's tested details (e.g. to EN 1366-3 / UL 1479)
  • Project builder's work in connection (BWIC) procedure

Assumptions

  • Clearance each side covers fire-stopping, installation tolerance and insulation continuity.

Inputs and units

Service—
Duct width (or pipe outside diameter)mm10–3000
Duct height (ducts only)mm
Insulation thicknessmm
Clearance each side (fire-stopping, tolerance)mm

Typical range: last column

Worked example (default values)

  • ServiceRound pipe
  • Duct width (or pipe outside diameter)114 mm
  • Duct height (ducts only)0 mm
  • Insulation thickness25 mm
  • Clearance each side (fire-stopping, tolerance)25 mm
Minimum sleeve / core diameter214 mm

Next steps

Found an error? Tell us

Describe the problem briefly (the wrong value, the right one, and the reference if you have it). The page name is sent automatically.