Civil & Structural

Concrete Grades: Cube vs Cylinder

European grading names concrete by two characteristic compressive strengths in MPa: cylinder first, then cube.

Reading the grade

  • C30/37: 30 MPa on 150 × 300 mm cylinders, 37 MPa on 150 mm cubes.
  • Cubes give higher results because the platen restraint is greater on a squat specimen.
  • Gulf specifications and testing labs usually work in cube strength, so confirm which value a drawing means.

Hot weather concreting

  • High temperature speeds setting, increases water demand and causes plastic shrinkage cracks.
  • Typical controls: chilled water or ice, night pours, retarders, wind breaks and immediate curing.
  • Many Gulf specifications cap concrete temperature at placing at around 32 °C. Check your project specification.

Common grades

GradeTypical use
C20/25Blinding (lower), non-structural slabs
C30/37General slabs, beams and columns
C40/50Foundations in aggressive soils, post-tensioned slabs
C50/60+High-rise columns, precast
Good to knowCubes are normally tested at 7 and 28 days. The 28-day result decides compliance.
Found an error? Tell us

Describe the problem briefly (the wrong value, the right one, and the reference if you have it). The page name is sent automatically.