Designs, checks or delivers building envelopes: curtain walls, cladding, glazing, louvres and roofs. Works between architects, structural engineers, fire engineers, suppliers and installers, from the performance specification to the last site water test.

Career path

  1. 1
    Graduate / site façade engineerInstallation checks, site tests, inspection records
  2. 2
    Façade engineerShop drawing and calculation reviews, thermal and glass checks
  3. 3
    Senior / lead façade engineerPerformance specifications, mock-ups, interface design
  4. 4
    Façade director / consultantStrategy, complex envelopes, expert advice

Core skills

Curtain wall and cladding systemsWind loads and member checksGlass types and performance (U, SHGC, VLT)Thermal and condensation analysis (THERM)Fire performance of façadesTesting (PMU, AAMA 501.2)Sealant and joint design

Recommended certificates

CertificateIssued byWhen
Local engineer registration (Qatar, Saudi Arabia, Egypt)National authorityEarly career
CWCT training coursesCWCTMid-career
Society of Façade Engineering membershipSFE / IStructEMid-career
Chartered Engineer (CEng)IStructE / ICE / IMechESenior
Career tipLearn to read a façade by looking at its joints. Almost every leak, crack and fire gap starts where two things meet.

Interview questions

How do you check a mullion for wind?

Take the design pressure from the wind study or code including corner zones, convert it to a line load with the tributary width, check deflection against the specified limit (often AAMA L/175 up to 4.1 m) and bending stress, then check brackets, anchors and the stack joint.

What makes a façade unsafe in fire, even with non-combustible panels?

Combustible insulation or membranes in the cavity, missing cavity barriers at floors and openings, and poor slab-edge fire stopping. The whole system must be shown to resist fire spread, with test evidence approved by civil defence.

Why start site water testing early?

So design or workmanship faults are found on the first floors and corrected before most panels are installed. Late testing finds the same fault repeated across the whole building.