HA Engineering Hub · Learn • Calculate • Check
Scientists study the world as it is. Engineers create the world that has never been.
— Theodore von Kármán, aerospace engineer
Free engineering calculators, guides, checklists and Excel tools, built on international standards, with local guidance for Qatar, Saudi Arabia and Egypt.
Free · no sign-up for calculators · standards cited · results are preliminary, verify before design
What are you trying to do?
Featured calculators
All calculators →Calculations
Ready calculators for every discipline
Engineering Topics
Standards, safety cards and lessons from failures
What's new
More resources
Electrical Center
Calculators, guides, checklists and exams for electrical and ELV engineers
Engineering Library
Codes, books, free resources and software
Careers & Certificates
Career paths, certificates and interview prep
Templates
Submittals, RFIs, method statements and reports
Glossary EN ↔ AR
Engineering terms in English and Arabic
Exam Corner
Practice quizzes for PMP, NEBOSH, LEED and more
Jobs Board
Engineering vacancies shared by members
Engineers Chat
Ask and share know-how by discipline
Engineering calculators
Electrical, mechanical, civil, plumbing, renewables and project controls. Every calculator opens with typical values filled in.
Electrical Center: calculators in design orderAbout these calculators
Each calculator shows the formula, the standards it follows (IEC, BS 7671, NFPA, ASHRAE, ACI and others), the assumptions behind the result, and a worked example with the default values. Results update as you type, and you can print a one-page calculation sheet for your file.
They are made for quick checks on site and early design in Qatar, Saudi Arabia, Egypt and the wider Gulf. Results are preliminary: confirm them with the project specification, the local authority rules and the manufacturer's data before final design.
Things you should know
Short, practical notes on standards, site safety, contracts and lessons from famous failures.
Build your engineering career
Pick a career path to see how it progresses, the skills and certificates it needs, and typical interview questions.
A shelf for every engineer
Key standards, recommended books, free online resources and the software each discipline uses.
Practice before the real exam
Short practice quizzes with instant scoring and explanations.
Ready formats for daily site work
Open a template, copy it, and paste it into Word, Excel or an email.
Excel sheets for site and design work
Each workbook has a blank sheet, a completed SAMPLE and a How-to-use tab. Fields marked project-defined follow your contract.
Document outlines
Engineering terms in English and Arabic
Search in either language. Useful for bilingual site teams and reports.
Engineering vacancies
Vacancies shared by members and recent postings from external job sites. Links open the original posting. Always verify the employer, and never pay to apply.
Site checklists
Tick items as you go. Your progress is saved in this browser.
Electrical Center
Everything on the site for electrical and ELV engineers in one place: calculators in the order you design, site guides, checklists, practice exams, careers and the standards to keep at hand.
مرجع سريع
الجداول التي يرجع إليها المهندسون يومياً في مكان واحد.
Cable current ratings
| Size (mm²) | Rating (A) |
|---|---|
| 2.5 | 32 |
| 4 | 42 |
| 6 | 54 |
| 10 | 75 |
| 16 | 100 |
| 25 | 127 |
| 35 | 158 |
| 50 | 192 |
| 70 | 246 |
| 95 | 298 |
| 120 | 346 |
| 150 | 399 |
| 185 | 456 |
| 240 | 538 |
| 300 | 621 |
Copper, XLPE, multicore, 3 loaded conductors, in free air on perforated tray (IEC 60364-5-52, method E), 30 °C ambient. Apply derating factors for your site.
AWG ↔ mm²
| AWG / kcmil | Area (mm²) | Nearest metric (mm²) |
|---|---|---|
| 14 | 2.08 | 2.5 |
| 12 | 3.31 | 4 |
| 10 | 5.26 | 6 |
| 8 | 8.37 | 10 |
| 6 | 13.3 | 16 |
| 4 | 21.2 | 25 |
| 2 | 33.6 | 35 |
| 1 | 42.4 | 50 |
| 1/0 | 53.5 | 50 |
| 2/0 | 67.4 | 70 |
| 3/0 | 85.0 | 95 |
| 4/0 | 107 | 120 |
| 250 kcmil | 127 | 120 |
| 350 kcmil | 177 | 185 |
| 500 kcmil | 253 | 240 |
American wire gauge and the nearest standard metric size.
Standard breaker ratings
| Type | Typical ratings (A) | Notes |
|---|---|---|
| MCB | 6, 10, 16, 20, 25, 32, 40, 50, 63 | Curve B: 3–5 In · C: 5–10 In · D: 10–20 In |
| MCCB | 100, 125, 160, 200, 250, 320, 400, 500, 630, 800, 1000, 1250, 1600 | Adjustable thermal-magnetic or electronic trip |
| ACB | 630, 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000, 5000, 6300 | Main incomers; short-time delay for selectivity |
Common ratings and instantaneous trip ranges (IEC 60898-1 for MCBs).
Typical illuminance levels
| Area | Lux |
|---|---|
| Office, writing and reading | 500 |
| Meeting room | 500 |
| Classroom | 300–500 |
| Corridor | 100 |
| Stairs | 150 |
| Toilets | 200 |
| Kitchen | 500 |
| Plant room | 200 |
| Store room | 100 |
| Car park traffic lanes | 75 |
| Warehouse picking | 300 |
Maintained illuminance, indicative values in line with EN 12464-1. Check the project specification.
Rebar weights and areas
| Bar (mm) | Area (mm²) | Weight (kg/m) | 12 m bar (kg) |
|---|---|---|---|
| 8 | 50 | 0.395 | 4.7 |
| 10 | 79 | 0.617 | 7.4 |
| 12 | 113 | 0.889 | 10.7 |
| 16 | 201 | 1.580 | 19.0 |
| 20 | 314 | 2.469 | 29.6 |
| 25 | 491 | 3.858 | 46.3 |
| 32 | 804 | 6.321 | 75.9 |
Weight = d² ÷ 162 kg/m.
Pipe sizes (DN ↔ inch)
| DN | Inch | Steel OD (mm) |
|---|---|---|
| 15 | ½ | 21.3 |
| 20 | ¾ | 26.9 |
| 25 | 1 | 33.7 |
| 32 | 1¼ | 42.4 |
| 40 | 1½ | 48.3 |
| 50 | 2 | 60.3 |
| 65 | 2½ | 76.1 |
| 80 | 3 | 88.9 |
| 100 | 4 | 114.3 |
| 125 | 5 | 139.7 |
| 150 | 6 | 168.3 |
| 200 | 8 | 219.1 |
| 250 | 10 | 273.0 |
| 300 | 12 | 323.9 |
Nominal sizes with the outside diameter of steel pipe (ISO 4200 / ASME B36.10).
IP ratings
| Digit | First (solids) | Second (water) |
|---|---|---|
| 0 | No protection | No protection |
| 1 | > 50 mm | Dripping water |
| 2 | > 12.5 mm (fingers) | Dripping, tilted 15° |
| 3 | > 2.5 mm (tools) | Spraying water |
| 4 | > 1 mm (wires) | Splashing water |
| 5 | Dust protected | Water jets |
| 6 | Dust tight | Powerful water jets |
| 7 | – | Temporary immersion (1 m) |
| 8 | – | Continuous immersion (beyond 1 m) |
IEC 60529: first digit solids, second digit water.
Common conversions
| From | To |
|---|---|
| 1 TR | 3.517 kW = 12,000 BTU/h |
| 1 kW | 1.341 HP |
| 1 bar | 100 kPa = 14.5 psi |
| 1 m³/h | 0.278 L/s = 4.40 US gpm |
| 1 L/s | 2.119 CFM |
| 1 m | 3.281 ft |
| 1 m² | 10.764 ft² |
| 1 kg | 2.205 lb |
| 1 kN | 0.102 tonne-force |
| °F | °C × 9/5 + 32 |
Values engineers convert most often.
Fiber types
| Type | Core / cladding (µm) | Jacket | Wavelengths (nm) | 10 Gb/s reach |
|---|---|---|---|---|
| OM1 | 62.5/125 | Orange | 850 / 1300 | ≈ 33 m |
| OM2 | 50/125 | Orange | 850 / 1300 | ≈ 82 m |
| OM3 | 50/125 | Aqua | 850 / 1300 | ≈ 300 m |
| OM4 | 50/125 | Aqua / violet | 850 / 1300 | ≈ 400 m |
| OM5 | 50/125 | Lime green | 850–953 (SWDM) | ≈ 400 m |
| OS2 | 9/125 | Yellow | 1310 / 1550 | 10 km + |
Typical values from TIA-568 / ISO/IEC 11801 and IEEE 802.3. Reach depends on the transceiver; check the datasheet.
Fiber colour code
| No. | Colour | No. | Colour |
|---|---|---|---|
| 1 | Blue | 7 | Red |
| 2 | Orange | 8 | Black |
| 3 | Green | 9 | Yellow |
| 4 | Brown | 10 | Violet |
| 5 | Slate (grey) | 11 | Rose (pink) |
| 6 | White | 12 | Aqua |
TIA-598 order for fibers in a tube (and tubes in a cable). Fibers 13–24 repeat the colours with a black stripe or tracer.
Fiber loss limits
| Item | Limit | Typical installed |
|---|---|---|
| Mated connector pair | 0.75 dB | 0.2 – 0.5 dB |
| Fusion splice | 0.3 dB | 0.05 – 0.1 dB |
| MM fiber at 850 nm | 3.5 dB/km | ≈ 2.5 dB/km |
| MM fiber at 1300 nm | 1.5 dB/km | ≈ 0.8 dB/km |
| SM fiber, inside plant | 1.0 dB/km | ≈ 0.35 dB/km |
| SM fiber, outside plant | 0.5 dB/km | ≈ 0.25–0.35 dB/km |
Maximum values for Tier 1 acceptance (TIA-568). Your project specification may be stricter.
Copper cable categories
| Category / class | Bandwidth | Typical application | Tester level |
|---|---|---|---|
| Cat5e / Class D | 100 MHz | 1 Gb/s | Level IIe |
| Cat6 / Class E | 250 MHz | 1 Gb/s; 10 Gb/s ≤ 55 m | Level III |
| Cat6A / Class EA | 500 MHz | 10 Gb/s | Level IIIe |
| Cat7A / Class FA | 1000 MHz | 10 Gb/s (shielded) | Level IV / V |
| Cat8 / Class I-II | 2000 MHz | 25/40 Gb/s ≤ 30 m | Level 2G |
Channel up to 100 m (90 m permanent link + 10 m cords) unless noted.
PoE classes
| Standard | Type | At switch (W) | At device (W) |
|---|---|---|---|
| 802.3af (PoE) | Type 1 | 15.4 | 12.95 |
| 802.3at (PoE+) | Type 2 | 30 | 25.5 |
| 802.3bt (PoE++) | Type 3 | 60 | 51 |
| 802.3bt (PoE++) | Type 4 | 90 | 71.3 |
Power at the switch port (PSE) and guaranteed power at the device (PD).
CCTV DORI levels
| Level | px/m | px/ft | Purpose |
|---|---|---|---|
| Detect | 25 | 8 | Person present |
| Observe | 62 | 19 | Activity visible |
| Recognise | 125 | 38 | Known person recognised |
| Identify | 250 | 76 | Unknown person identified |
EN 62676-4 pixel densities on the target.
Common drawing symbols
Typical symbols with their names in English and Arabic. Always check the legend on your project drawings.
Engineering news and events
Recent project and industry headlines, and the major exhibitions coming up. Updated weekly.
Latest news
Upcoming events
Dates come from organiser and listing sites. Confirm on the official website before booking travel.
Ask a technical question
Get an instant answer on electrical, mechanical, civil, plumbing, contracts, safety or careers. Ask in English or Arabic.
Answers are generated by AI and are not reviewed by an engineer. Each answer lists its sources and what to verify. Use it to learn and to prepare questions, not as a design approval.
Ask, answer, share
Pick a channel for your discipline. Be specific: state the standard, voltage, load or location you are working with.
Answers here come from members and are not reviewed. Check them against the standard, the project specification and a qualified engineer before using them.